International and Indian Standards for Ring main Unit
.
Ring Main Unit (RMU) in High Voltage Systems: Components, Functions & Standards
Learn
about Ring Main Units (RMU) in high-voltage systems – their components,
functions, and applicable Indian and international standards. Essential for HT
customers and transformer protection.
🔹 What is a Ring Main Unit (RMU)?
A Ring
Main Unit (RMU) is an integral part of high-voltage (HV) and high-tension
(HT) power distribution systems. It is widely used in HT networks where
multiple consumers are connected to the same feeder line. The RMU ensures
uninterrupted supply, easy switching, and effective protection of transformers.
RMUs
serve two major purposes:
- Supplying power to distribution
transformers
- Providing protection for
transformers and switchgear
🔹 Components of a Ring Main Unit
An RMU
typically consists of:
- Load Break Switch (LBS) /
Circuit Breaker
(Vacuum type or SF6 gas type)
- Earth Switch
- Isolators
Important Note on SF6 Gas:
SF6
gas-insulated RMUs are mostly maintenance-free. The only critical check
is the SF6 gas pressure indicator.
- If the pointer shows green,
the breaker can operate safely.
- If it shows red, the
breaker must not be operated, as doing so could cause an explosion.
🔹 Why Use RMUs in HT Systems?
- Reliability: Enables uninterrupted power
even if one section of the network is under maintenance.
- Safety: Provides protection to
transformers against overloads and faults.
- Compact Design: Saves space compared to
traditional switchgear.
- Maintenance-Free: Especially in SF6
gas-insulated types.
🔹 Applicable Standards, Rules, and
Codes for RMUs
The
design, manufacturing, testing, and operation of Ring Main Units are governed
by both Indian Standards (IS) and International Electrotechnical
Commission (IEC) standards.
Standard / Rule |
Title |
Indian
Electricity Rules |
With
latest Amendments |
Indian
Electricity Act, 2003 |
Legal
framework for electricity supply |
IS 3427 |
A.C.
Metal enclosed switchgear & control gear above 1 kV |
IS 9920
(Part 1, 3 & 4) |
High
voltage switches above 1 kV |
IS
13118 |
General
requirements of circuit breakers above 1 kV |
IS 3231 |
Electric
relays for power system protection |
IEC
60265 (Part 1) |
High-voltage
switches |
IEC
60056 |
High-voltage
AC circuit breakers |
IEC
60059 |
Preferred
current ratings of HV switchgear |
IEC
60185 |
Current
transformers |
IEC
60694 |
Specifications
for HV switchgear |
IEC
60298 |
A.C.
Metal enclosed switchgear |
IEC
60129 |
A.C.
Disconnector and Earth Switches |
IEC
60529 |
Degree
of protection (IP ratings) for enclosures |
IS/IEC
62271-102 (2003) |
HV
Switchgear and Controlgear – Disconnectors & Earthing Switches |
IEC
60255 |
Electrical
relays |
✅ These standards ensure safe design, reliable operation, and proper
protection schemes in HT switchgear applications.
🔹 Conclusion
The Ring
Main Unit (RMU) plays a vital role in modern high-voltage distribution
networks. It improves system reliability, ensures safety, and provides
transformer protection with minimal maintenance. Adhering to the
above-mentioned IS and IEC standards is crucial for manufacturers,
utility companies, and engineers to guarantee safe and efficient HT
operations.